✅ Selmo audit checklist – Functional safety & standards compliance

✅ Selmo audit checklist – functional safety & standards compliance

This checklist is used for the structured review of a project that was modelled and implemented with Selmo Standard It can be used for:

  • internal approvals,

  • external audits,

  • CE documentation reviews,

  • project releases.


🔍 1. Model structure & composition

Acceptance criterion

Compliant?

Remark

Machine fully represented as Selmo model (PLANT → HWZ → SEQ → Zone)

✅ / ❌

Each zone assigned unambiguously (type, IO, signal, terminal)

✅ / ❌

Each SEQ modelled as a state graph with valid transitions

✅ / ❌

Bit control fully filled out (0, S, i)

✅ / ❌


🔍 2. Functional logic & sequence control

Acceptance criterion

Compliant?

Remark

Each state named uniquely and logically

✅ / ❌

Sequence is deterministic (no jumps outside the model)

✅ / ❌

Interlocks (i) set sensibly and safely

✅ / ❌

Sequence checks (S) used correctly

✅ / ❌

Timers, repeaters, decisions parameterized correctly

✅ / ❌


🔍 3. Safety functions

Acceptance criterion

Compliant?

Remark

CMZ zones set correctly on SEQ/HWZ/PLANT

✅ / ❌

MXIC matrix present, complete, traceable

✅ / ❌

Fault reaction on i and CMZ violation correct

✅ / ❌

Reset logic clearly represented in the model

✅ / ❌

Restart only possible in a valid state + release

✅ / ❌


🔍 4. HMI, operation & diagnostics

Acceptance criterion

Compliant?

Remark

SEQ control shows current state & next step

✅ / ❌

Error display localized with HMI text, color and zone

✅ / ❌

Button behaviour secured by MXIC

✅ / ❌

Stepwise operation possible in manual mode

✅ / ❌

Automatic start only with valid process state

✅ / ❌


🔍 5. Documentation & export

Acceptance criterion

Compliant?

Remark

IO mapping complete (Zone ↔ Address ↔ Terminal)

✅ / ❌

Parameter list with IN / OUT / INOUT complete

✅ / ❌

CMZ and MXIC definition exported

✅ / ❌

Change log (Model_ChangeLog.csv) present

✅ / ❌

Exported documentation matches the model

✅ / ❌


🔍 6. Standards compliance (verifiable)

Acceptance criterion

Compliant?

Standards reference

Remark

Operating modes modelled, switchable, safe

✅ / ❌

ISO 12100

Safety functions documented & verifiable

✅ / ❌

EN ISO 13849, IEC 62061

Restart behaviour CE-compliant

✅ / ❌

ISO 12100, Machinery Regulation

PLC code generated from model, IEC 61131-3 compliant

✅ / ❌

IEC 61131-3

Risk assessment can be linked to the model

✅ / ❌

ISO 12100


📝 Conclusion

  • Review performed on: _____________

  • Project name / model version: _____________

  • Reviewer / role: _____________

  • Status: 🔲 passed 🔲 with conditions 🔲 failed

Signature / approval: __________________________