✅ Selmo PTF – Output & Customer checklist

1. Purpose of the checklist

This checklist serves to Ensure completeness, quality and usability of all PTF results. It describes:

  • Which Outputs arise from the PTF process,

  • How they are approved and distributed Non-Selmo-compliant technologies can be identified

  • And which Customer (Stakeholder) use the results in which form use.


2. Output checklist

No.
PTF output
Description
Mandatory / optional
Format
Released by
Check criteria

1

PTF report (complete document)

Summary of all PTF results (Process, Technology, Function)

Mandatory

PDF / DOCX

Project management / PTF lead

Complete, consistent, approved

2

PTF model data (structural model)

Exported machine model (Plant → HWZ → Sequence → Zones → Bit-Control)

Mandatory

XML / PLCopen / JSON

Automation / PTF lead

Structure complete, importable into Selmo

3

PTF-RISK

Risk assessment of all deviations and non-Selmo conformities

Mandatory

Excel / PDF

Quality / Safety

Risks assessed, measures defined

4

PTF-RELEASE

Formal approval for implementation (signatures of all responsible parties)

Mandatory

PDF

Project management / customer

Signed, approved, versioned

5

PTF-FUNC

Complete function sheets (inputs, outputs, limits, test cases)

Mandatory

XML / PDF

Automation / Quality

Testable, tested, documented

6

PTF-HMI

Operating concept with HMI texts, colors, messages and diagnostics

Optional

CSV / JSON

Maintenance / Quality

HMI texts correctly assigned

7

PTF-TECH

Technology matrix with components, media, interfaces

Mandatory

Excel / PDF

Mechanics / Electrical

All components represented

8

PTF-IF

Interface description to external systems (MES, ERP, SCADA)

Mandatory

JSON / YAML

IT / OT

Communication structure defined

9

PTF-SAFE

Safety logic (interlocks, CMZ, MXIC, PLr/SIL)

Mandatory

Excel / PDF

Safety / CE

Safety concept complete and traceable

10

PTF-Q

Quality plan and test strategy (SPC, limit patterns, DoE)

Optional

Excel / PDF

Quality

Test processes defined

11

PTF-FINAL / Lessons Learned

Documentation after completion (audit trail, improvements)

Optional

PDF

PTF lead / Project management

Complete traceability

12

PTF-NORM / Compliance

Proof of considered standards and guidelines (MVO 2027, ISO 12100 etc.)

Mandatory

PDF

Quality / CE

Standards listed, conformity assessed


3. Testing and approval criteria for outputs

Before approval the following points must be met:


4. Distribution / storage of outputs

Recommended directory structure:

  • /PTF/Output/

    • PTF-Report_v1.0.pdf

    • PTF-Model_v1.0.xml

    • PTF-RISK_v1.0.xlsx

    • PTF-RELEASE_v1.0.pdf

    • PTF-FUNC_v1.0.xml

    • PTF-SAFE_v1.0.xlsx

    • PTF-HMI_v1.0.csv

    • PTF-IF_v1.0.json

    • PTF-NORM_v1.0.pdf

Distribution recommendation:

  • All stakeholders receive access via a central repository (e.g., Git, SharePoint, PLM system).

  • Only approved documents may be distributed (status: Released).

  • Archiving requirement for every approved version.


5. Customer checklist

This overview describes, who uses the PTF results, for what, and which concrete benefit they derive from it.

No.
Customer / Stakeholder
Uses / requires
Purpose
Benefit
Responsible for feedback

1

Project management / PTF lead

Entire PTF report, PTF-RISK, PTF-RELEASE

Project control, Quality, Decision-making

Transparency, control, traceability

Project management

2

Process owner (IE)

PTF-PROC, PTF-PARAM, PTF-FUNC

Process validation, parameter alignment

Process quality, early fault detection

Process owner

3

Mechanics / Design

PTF-TECH, PTF-IO

Implementation and layout coordination

Avoidance of design errors

mechanics

4

Electrical / control

PTF-IO, PTF-SAFE, PTF-IF

Hardware integration, addressing

Clear assignment of signals

Electrical

5

Software / automation

PTF-FUNC, PTF model data

Creation of the Selmo process model

Deterministic programming, code traceability

Automation

6

Quality / Safety / CE

PTF-RISK, PTF-SAFE, PTF-NORM

Audit, risk assessment, CE documentation

Standards compliance, demonstrability

Quality / CE

7

IT / OT / MES / ERP

PTF-IF, PTF model data

Communication and data integration

Early system tests, stable data exchange points

IT / OT

8

Operation / Maintenance

PTF-HMI, PTF-FUNC, PTF-RISK

Operation, diagnosis, training

Transparent maintenance, reduced downtime

Maintenance

9

Management / Controlling

PTF-Report, PTF-RISK, PTF-RELEASE

Economic evaluation, governance

Project decisions, budget transparency

Management

10

Customer / Operator

PTF-Report, PTF-NORM, PTF-FINAL

Acceptance, operation, audit

Trust, proof of safety and quality

Customer / Operator


6. Approval and communication process

  1. PTF outputs created → by specialist departments

  2. Internal review → by PTF lead, Quality and Safety

  3. Review meeting → all disciplines present

  4. Deviations documented → PTF-RISK updated

  5. Approval → PTF-RELEASE signed

  6. Distribution → central storage + access for all customers

  7. Feedback / Lessons Learned → collected in PTF-FINAL


7. Use of outputs during the project

Phase
Use of the outputs

After PTF release

Basis for Selmo modeling and digital twin

During design

Reference for signal definition and hardware concept

Before commissioning

Preparation SoftFAT / simulation

During operation

Use of HMI, diagnostics, parameter management

In audit / CE inspection

Proof of standards compliance

In service

Fault diagnosis, change management


8. Completion criteria for the output

A PTF is considered fully completed, when:

  • All PTF documents are created, reviewed and approved

  • The PTF report is archived as version “Released”

  • The Selmo model can be imported without deviations

  • All deviations are assessed and documented

  • The customer / operator has acknowledged or confirmed the results


9. Conclusion

The Output of the PTF is not a paper document, but a digital twin of the machine logic – complete, verifiable and deterministic.

The Customer receive from it:

  • Process clarity (Process & logic visible),

  • Risk transparency (assessed & documented),

  • equivalent (from requirement to behavior),

  • trust (through standards compliance & data quality).

The PTF output is the link between engineering and operations, and the basis for Software, audit, quality and digital simulation in the Selmo system.

Last updated

Was this helpful?